Model | MATAHARI-70K-G03 | MATAHARI-75K-G03 | MATAHARI-80K-G03 | MATAHARI-90K-G03 | MATAHARI-100K-G03 | MATAHARI-110K-G03 | | | | | | | |
Maks. Daya Masukan DC (kW) | 91 | 97,5 | 104 | 135 | 150 | 150 | | | | | | | |
Maks. Tegangan Masukan DC (V) | 1000 | | | | | | | |
Tegangan Input DC Pengaktifan (V) |
250
| | | | | | | |
Rentang Operasi MPPT (V) |
200~850
| | | | | | | |
Maks. Arus Masukan DC (A) | ' 40+40+40+40 |
40+40+40+40+40+40
| | | | | | | |
Maks. Arus Hubung Pendek (A) |
60+60+60+60
|
60+60+60+60+60+60
| | | | | | | |
Jumlah Pelacak MPP | 4 | 6 | | | | | | | |
Jumlah String per Pelacak MPP |
4
| | | | | | | |
Sisi Keluaran | | | | | | | | |
Nilai Daya Keluaran (kW) | 70 | 75 | 80 | 90 | 100 | 110 | | | | | | | |
Maks. Daya Aktif (kW) | 77 | 82.5 | 88 | 99 | 110 | 121 | | | | | | | |
Tegangan/Rentang Keluaran Nominal (V) |
3L/N/PE 220/380V, 230/400V
| | | | | | | |
Nilai Frekuensi Jaringan (Hz) |
50/60 (Opsional)
| | | | | | | |
Fase Operasi | Tiga fase | | | | | | | |
Nilai Arus Keluaran Jaringan AC (A) | 106.1/101.5 | 113.6/108.7 | 121.2/115.9 | 136.4/130.4 | 151.5/144.9 | 166.7/159.4 | | | | | | | |
Maks. Arus Keluaran AC (A) | 116.7/111.6 | 125/119.6 | 133.3/127.5 | 150/143.5 | 166.7/159.4 | 183.3/175.4 | | | | | | | |
Faktor Daya Keluaran |
0,8 mengarah ke 0,8 tertinggal
| | | | | | | |
Jaringan THD Saat Ini | <3% | | | | | | | |
Arus Injeksi DC (mA) |
<0,5%
| | | | | | | |
Rentang Frekuensi Jaringan |
47~52 atau 57~62 (Opsional)
| | | | | | | |
Efisiensi | | | | | | | | |
Maks. Efisiensi | 98,8% | | | | | | | |
Efisiensi Euro | 98,3% | | | | | | | |
Efisiensi MPPT | >99% | | | | | | | |
Perlindungan | | | | | | | | |
Perlindungan Polaritas Terbalik DC | Ya | | | | | | | |
Perlindungan Sirkuit Pendek AC | Ya | | | | | | | |
Perlindungan Arus Berlebih Keluaran AC |
Ya
| | | | | | | |
Perlindungan Tegangan Lebih Keluaran |
Ya
| | | | | | | |
Perlindungan Resistansi Isolasi | Ya | | | | | | | |
Pemantauan Kesalahan Tanah | Ya | | | | | | | |
Perlindungan Anti-pulau | Ya | | | | | | | |
Perlindungan Suhu | Ya | | | | | | | |
Sakelar DC Terintegrasi | Ya | | | | | | | |
Unggah perangkat lunak jarak jauh | Ya | | | | | | | |
Perubahan jarak jauh pada parameter operasi | Ya | | | | | | | |
Perlindungan lonjakan arus | DC Tipe II / AC Tipe II | | | | | | | |
Data umum | | | | | | | | |
Ukuran (mm) |
838W×568H×324D
| 838W×568H×346D | | | | | | | |
Berat (kg) | 81 | | | | | | | |
Topologi | Tanpa transformator | | | | | | | |
Konsumsi Internal |
<1W (Malam)
| | | | | | | |
Suhu Berjalan |
-25~65℃, penurunan daya >45℃
| | | | | | | |
Perlindungan Masuknya | IP65 | | | | | | | |
Emisi Kebisingan (Khas) |
<55dB
| | | | | | | |
Konsep Pendinginan | Pendinginan cerdas | | | | | | | |
Maks. Ketinggian Pengoperasian Tanpa Penurunan Daya |
2000m
| | | | | | | |
Jaminan | 5 tahun | | | | | | | |
Standar Sambungan Jaringan | CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 | | | | | | | |
Kelembaban Lingkungan Pengoperasian |
0-100%
| | | | | | | |
Keselamatan EMC / Standar |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
| | | | | | | |